Direkt zum Inhalt springen
Computer Vision Group
TUM Department of Informatics
Technical University of Munich

Technical University of Munich

Menu

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

data:datasets:rgbd-dataset:intrinsic_calibration [2011/08/04 17:13] (current)
sturmju created
Line 1: Line 1:
 +====== Intrinsic Camera Calibration of the Kinect ======
  
 +The Kinect has a factory calibration stored onboard, based on a high level polynomial warping function. The OpenNI driver uses this calibration for undistorting the images, and for registering the depth images (taken by the IR camera) to the RGB images. Therefore, the depth images in our datasets are reprojected into the frame of the color camera, which means that there is a 1:1 correspondence between pixels in the depth map and the color image. ​
 +
 +As a result, the conversion from the 2D images to 3D point clouds is the same for all datasets:
 +
 +<​code>​
 +focalLength = 525.0
 +centerX = 319.5
 +centerY = 239.5
 +
 +for v in range(depth_image.height):​
 +  for u in range(depth_image.width):​
 +    X = (u - centerX) * depth_image[v,​u] / depthFocalLength;​
 +    Y = (v - centerY) * depth_image[v,​u] / depthFocalLength;​
 +    Z = d;
 +</​code>​